Delay - The number of seconds to delay between failover attempts. The default is 10 seconds. The following list is an explanation of the fields found on the Workarounds Options tab shown in the preceding graphic:. This support is disabled by default. ODBC calls made by the application to specifically change the value of the attribute after connection time are unaffected by this option and complete their functions as expected.
By default, this option is off. This enhancement improves the performance of Oracle ODBC driver up to 10 times, depending on the prefetch size set by the user. The default value is 0. The maximum value that you can set is 64 KB bytes.
If the value of prefetch size is greater than , the data fetched is only bytes. If you pass a buffer size less than the prefetch size in nonpolling mode, a data truncation error occurs if the LONG data size in the database is greater than the buffer size. By default, this function is enabled. A subprogram call specified in an EXEC statement is translated to its equivalent Oracle subprogram call before being processed by an Oracle database server.
By default this option is disabled. Schema , which is the translated Oracle subprogram assumed to be defined in the user's default schema. However, if all subprograms from the same SQL Server database are migrated to the same Oracle schema with their database name as the schema name, then set this field to database.
If all subprograms owned by the same SQL Server user are defined in the same Oracle schema, then set this field to owner. This field is empty by default. An Oracle server waits indefinitely for lock conflicts between transactions to be resolved. The value you enter for the LockTimeOut parameter is the number of seconds after which an Oracle server times out if it cannot obtain the requested locks.
In the following example, the Oracle server times out after 60 seconds:. As part of the connection process, an application can prompt you for information. If an application prompts you for information about an Oracle data source, do the following:. An application must connect to a data source to access the data in it. Different applications connect to data sources at different times. For example, an application might connect to a data source only at your request, or it might connect automatically when it starts.
For information about when an application connects to a data source, see the documentation for that application. If you try to connect to the database and your password has expired, you are prompted to change your password. Upon making a successful password change, you are connected to the database. Instead, an error condition results, producing an error message and number that indicates that the password has expired.
In addition to Oracle's grammar, the vendor-specific escape sequences outlined in Appendix C of the ODBC specifications are also supported. When connected to a Table describes these limitations. The limiting factor is the client workstation memory.
Oracle database allows only a single long data column per table. The driver derives this information both from errors detected by the driver and errors returned by the Oracle server. For errors that occur in the data source, the Oracle ODBC Driver returns an error message based on the message returned by the Oracle server. The prefixes in brackets [ ] identify the source of the error. When the error occurs in the data source, the [vendor] and [ODBC-component] prefixes identify the vendor and name of the ODBC component that received the error from the data source.
For example, if the error message does not contain the [Ora] prefix shown in the following format, the error is an Oracle ODBC Driver error and should be self-explanatory. Although the error message contains the [Ora] prefix, the actual error may be coming from one of several sources. If the error message text starts with the following prefix, you can obtain more information about the error in the Oracle server documentation. The following table describes keywords that can be included in the connection string argument of the SQLDriverConnect function call.
Missing keywords are read from the Administrator entry for the data source. Values specified in the connection string override those contained in the Administrator entry. Sets the token size to the nearest multiple of 1 KB bytes beginning at 4 KB bytes. If the following keyword is specified in the connection string, the Oracle ODBC Driver does not read values defined from the Administrator:.
For more information, see the Oracle Net Services documentation. The Oracle server waits indefinitely for lock conflicts between transactions to be resolved. Reducing Lock Timeout for more information on specifying a value in the oraodbc.
For Windows platforms, when you link your program, you must link it with the import library odbc However, the rowid value must be presented in a parameter marker. Oracle reference cursors Result Sets allow an application to retrieve data using stored procedures and stored functions. The ODBC syntax for calling stored procedures must be used. The following identifies how to call the procedure or function without a package and within a package. The package name in this case is RSET.
For example, assume procedure Example2 is defined to have four parameters. Parameters 1 and 3 are reference cursor parameters and parameters 2 and 4 are character strings. The call is specified as:.
Contents Exit focus mode. Please rate your experience Yes No. Any additional feedback? Important This feature will be removed in a future version of Windows. Submit and view feedback for This product This page. View all page feedback. Privacy policy. Starting with version Version If you are accessing this page from a non-English language version, and want to see the most up-to-date content, please select Read in English at the top of this page.
You can download different languages from the US-English version site by selecting available languages. Later it was maintained by Julie Ann Case. As part of a commercial research project,the developers at Insight DistributionsSystem overhauled the driver.
Their goal was to make the drivercommercially viable. In keeping with the spirit with whichthe original source was acquired, Insight published their work at theirwebsite. The driver continued to be maintained by Byron Nikolaidis, the developer at Insight who overhauled the driver for some time.
By way of example, but not limitation, M. This can be done from the Oracle site using the following links. You will need to have a signon to Oracle in order to do this.
0コメント